Send Message
Home ProductsMultifunction Process Calibrator

R Thermocouple Multifunction Process Calibrator

Certification
China XI'AN BEICHENG ELECTRONICS CO.,LTD certification
China XI'AN BEICHENG ELECTRONICS CO.,LTD certification
Customer Reviews
In general, very satisfied. Packed all on conscience. Thank you to the seller for the prompt answers in the selection of goods. As for the quality of the goods, there is no smell, and there is no feeling of cheap. Everything is done well enough. The call is clear loud.

—— Alexander

Хороший мультиметр с вполне приемлемой точностью и хорошим функционалом. Щупы толстые, мягкие, с низким сопротивлением. Правда сам металлический кончик уж очень маленький - порядка 2мм., как то несколько не удобно. В целом всё хорошо.

—— Maria

Gute Produkte, zuverlässiger Verkäufer, Kundenservice war top , alle meine Fragen wurden schnell beantwortet.würde ich auf jeden Fall weiter empfehlen.

—— Yanik

Excellent multimeter, measures, exactly, current consumption when turning on 1.7ma, in 25mA mode, the build quality is good, the switch of operating modes switches gently. Of the minuses, power is 9V, and piquant when switching

—— Natasha Santiesteban

Perfect multimeter with very good quality. For this price nothing can beat this! 4 days delivery from the order. I am maximally satisfied! Recommended product, recommended seller! Thank you

—— Fernando Rodríguea

I'm Online Chat Now

R Thermocouple Multifunction Process Calibrator

R Thermocouple Multifunction Process Calibrator
R Thermocouple Multifunction Process Calibrator R Thermocouple Multifunction Process Calibrator R Thermocouple Multifunction Process Calibrator R Thermocouple Multifunction Process Calibrator R Thermocouple Multifunction Process Calibrator R Thermocouple Multifunction Process Calibrator R Thermocouple Multifunction Process Calibrator

Large Image :  R Thermocouple Multifunction Process Calibrator

Product Details:
Place of Origin: CHINA
Brand Name: VICTOR
Certification: CE
Model Number: VICTOR 02+
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Price: USD115/pc
Packaging Details: 10pcs/Carton; Carton Size: 39.5*38.5*26cm; 10KG/carton
Delivery Time: 5 to 30 days
Payment Terms: T/T, Western Union, L/C, Paypal
Supply Ability: 3000pcs available

R Thermocouple Multifunction Process Calibrator

Description
Color: Blue Or Orange And Black Size: 180*90*47mm
Product Name: Temperature Source Model No.: VICTOR 02+
Material: Plastic, Metal, Silica Gel Packing Details: 10pcs/Carton; Carton Size: 39.5*38.5*26cm
Accuracy: 0.05% Accuracy Weight: Approx. 900 G (including Batteries)
Power Supply: 2*1.5V AA Alkaline Battery
High Light:

R Thermocouple Multifunction Process Calibrator

,

K Thermocouple Multifunction Process Calibrator

,

R Thermocouple multifunction calibrator

VICTOR 02+ Thermocouple Calibrator Imput And Output Source 8 Types Of Thermocouple Measurement (R/S/K/E/J/T/B/N)

 

VC02+THERMOCOUPLE CALIBRATOR

  • Output and measurement with basic accuracy of 0.05%. 5 digits display for measured value. With resolution of 0.1℃ the output unit can be converted between ℃ and ℉.

  • Measurements: DC voltage, 8 types of thermocouple measurement (R/S/K/E/J/T/B/N).

  • Outputs: DC voltage, 8 types of thermocouple outputs (R/S/K/E/J/T/B/N).

  • Temperature compensation with high accuracy at the cold terminal is designed for measurement and output of thermocouple.

  • The phase compensation of output make it possible for instrument to drive a load with capacitance up to 2000µf, matching for application with the filter of large capacitance at the input terminal.

  • Adjustable output gain, easy in operation.

  • Built-in self-tests with closed-case calibration (no internal calibration adjustment).

Output function and technical index

 

Output

Range

Output range

Resolution

Accuracy

Illustration

DCV

100mV

-10.00~110.00mV

0.01mV

0.05%+30uV

Max. output current ±2mA

1V

-0.1000~1.1000V

0.1mV

0.05%+0.3mV

TC

R

-40~1760℃

1℃

0.05%+3(less than or equals to 100°C)

0.05%+2(more than 100°C)

Employs ITS-90 temperature standard

The accuracy does not include the error of interior temperature compensation sensor

The accuracy does not include the impact of interior thermoelectric force

S

-20~1760℃

1℃

 

RTD

B

400~1800℃

1℃

0.05%+3(less than or equals to 600°C)

0.05%+2(more than 600°C)

E

-200.0~1000.0℃

0.1℃

0.05%+20(less than or equals to -100°C)

0.05%+10(more than -100°C)

K

-200.0~1370℃

0.1℃

J

-200.0~1200.0℃

0.1℃

T

-200.0~400.0℃

0.1℃

N

-200.0~1300.0℃

0.1℃

 

 

Input function and technical index

 

Input

Range

Output range

Resolution

Accuracy

Illustration

DC voltage

DCmV

100mV

-10.00~110.00mV

0.01mV

0.05%+3

Input resistance:1MΩ

thermocouple

TC

R

-40°C~1760°C

1°C

0.05%+3(less than or equals to 100°C)

0.05%+2(more than 100°C)

Input resistance :1MΩ

Employs ITS-90 temperature standard

The accuracy does not include the error of interior temperature compensation sensor

The accuracy does not include the impact of interior thermoelectric force

S

-200°C~1760°C

B

400°C~1800°C

0.05%+3(less than or equals to 600°C)

0.05%+2(more than 600°C)

K

-200.0°C~1370.0°C

0.1°C

0.05%+20(less than or equals to -100°C)

0.05%+10(more than -100°C)

E

-200.0°C~1000.0°C

J

-200.0°C~1200.0°C

T

-200.0°C~400.0°C

N

-200.0°C~1300.0°C

 

General feature

  • power

:

two 1.5V alkaline batteries(LR6)

l power consumption

:

about 50m/3V

  • maximum allowed voltage

:

30V(within terminals or between terminal and earth ground)

  • operation temperature range

:

0°C~50°C

  • operation humidity range

:

≤ 80%RH

  • storage temperature range

:

≤ - 10°C~55°C

  • storage humidity range

:

≤ 90%RH

  • temperature coefficient

:

0.1×(dedicated accuracy)%/℃(5℃~18℃,28℃~40℃)

  • measurement

:

180(L)×90(W)×47(D)mm(with protector)

  • weight

:

about 500g

  • accessory

:

User’s Manual, industrial testing lead CF-36 (clips for probe)

  • safety

:

complies with IEC1010 (safety standard issued by International Electrician Committee)


R Thermocouple Multifunction Process Calibrator 0

Product Details:

R Thermocouple Multifunction Process Calibrator 1R Thermocouple Multifunction Process Calibrator 2

Packing And Accessories:

R Thermocouple Multifunction Process Calibrator 3

Contact Details
XI'AN BEICHENG ELECTRONICS CO.,LTD

Contact Person: sales

Tel: +86 13924679853

Fax: 86-755-82268753-262

Send your inquiry directly to us (0 / 3000)