Product Details:
|
Color: | Blue Or Orange And Black | Size: | 206 × 97× 60 Mm |
---|---|---|---|
Product Name: | Multifunction Process Calibrator | Model No.: | VICTOR 26 |
Packing Details: | 6pcs/Carton; Carton Size: 53*40.5*31cm | Accuracy: | 0.01% Accuracy |
Weight: | Approx. 633g (including Batteries) | Protection: | IP65 |
DCI output manual-step, auto-step and auto-ramping output functions.
Built-in 24V loop circuit.
Input Measurement Function [adapt to one year after calibration 23℃±5℃,20~70% RH,accuracy=±(% readings + % range)]
measurement function | range | measurement range | resolution | accuracy | remark |
DC voltage DCV |
50mV |
-5.000mV~ 55.000mV |
1μV | 0.01+0.01 | Input resistance: about 100MΩ |
500mV |
-50.00mV~ 550.00mV |
10μV | 0.01+0.01 | ||
5V |
-0.5000V~ 5.5000V |
0.1mV | 0.01+0.01 | Input resistance: about 1MΩ | |
30V |
-5.000V~ 35.000V |
1mV | 0.01+0.01 | ||
DC current DCI |
50mA |
-5.000mA~ 55.000mA |
1μA | 0.01+0.01 | shunt resistance: about 10Ω |
Ohms OHM (4W) |
500Ω | 0.00Ω~550.00Ω | 0.01Ω | 0.01+0.01 |
500Ω about 1mA simulation 5KΩ about 0.1mA simulation open-loop voltage: about 2.5V wire resistance is excluded in the accuracy |
5KΩ |
0.0000 KΩ~ 5.5000KΩ |
0.1Ω | 0.01+0.01 | ||
frequency FREQ |
50KHz | 3Hz~50.00000KHz | 0.01Hz | 0.01+0.00004 |
input resistance: more than 100 kΩ frequency sensitivity: square wave is 3V Vp-p at least 50% duty ratio |
CPM | 180~3000000 CPM | 1CPM | ±2个字 | ||
Thermal couple TC |
R* | 0°C~1767°C | 1°C |
0~500℃ : 1.8℃ 500~1767℃ : 1.5℃ |
Employ ITS-90 temperature standard Errors for cold-end compensation is excluded in the accuracy |
S* | 0°C~1767°C | ||||
K | -100.0°~1372.0°C | 0.1°C |
-100.0~0.0℃ : 1.2℃ 0.0~1372.0℃ : 0.8℃ |
||
E | -50.0°C~1000.0°C |
-50.0℃~0.0℃ : 0.9℃ 0.0~1000.0℃ : 1.5℃ |
|||
J | -60.0°C~1200.0°C |
-60.0~0.0℃ : 1.0℃ 0.0~1200.0℃ : 0.7℃ |
|||
T | -100.0°C~400.0°C |
-100.0~0.0℃ : 1.0℃ 0.0~400.0℃ : 0.7℃ |
|||
N | -200.0°~1300.0°C |
-200.0~0.0℃ : 1.5℃ 0.0~1300.0℃ : 0.9℃ |
|||
B* | 600°C~1820°C | 1°C |
600~800℃ : 2.2℃ 800~1000℃ : 1.8℃ 1000~1820℃ : 1.4℃ |
||
L | -60.0°C~900.0°C | 0.1°C |
-60.0~0.0℃ 0.7℃ 0.0~900.0℃ 0.5℃ |
||
U | -100.0°C~600.0°C | 0.1°C |
-100.0~0.0℃ 0.7℃ 0.0~600.0℃ 0.5℃ |
||
Resistance temperature RTD
|
Pt100 385 |
-200.0°C~800.0°C | 0.1°C |
-200.0~0.0℃ : 0.5℃ 0.0~400.0℃ : 0.7℃ 400.0~800.0℃ : 0.8℃ |
Employ ITS-90 temperature standard Errors due to the mismatch of lead resistance for lead resistance, 3-wired or 4-wired measurements are excluded in the accuracy |
Pt1000 385 |
-200.0°C~630.0°C |
-200.0~100.0℃: 0.3℃ 100.0~300.0℃ : 0.5℃ 300.0~630.0℃ : 0.7℃ |
|||
Pt200 385 |
-200.0°C~630.0°C |
-200.0~100.0℃: 0.8℃ 100.0~300.0℃ : 0.9℃ 300.0~630.0℃ : 1.0℃ |
|||
Pt500 385 |
-200.0°C~630.0°C |
-200.0~100.0℃: 0.4℃ 100.0~300.0℃ : 0.5℃ 300.0~630.0℃ : 0.7℃ |
|||
Cu10 | -100.0°C~260.0°C | 1.8℃ | |||
Cu50 | -50.0°C~150.0°C | 0.7℃ | |||
Pulse counting PULSE |
100000 cycles | 1~100000cycles | 1cycle | ±2个字 | see the related indexes for frequency |
switch volume measurement SWITCH |
CLOSE / OPEN |
about 1mA simulation short circuit displays CLOSE open circuit displays OPEN the threshold value is about 200~300Ω |
|||
Continuity test CONNECT |
500Ω | ≤ 50Ω vocalize | 0.01Ω |
500Ω about 1mA simulation |
|
Loop supply LOOP |
24 V | 10% |
short circuit protection Max circuit : 22 mA Max input voltage: 30 V DC output resistance: 250Ω nominal value |
Other features:
Simulation Output Function [adapt to one year after calibration 23℃±5℃, 20~70%RH ,accuracy=±(% settings + range %)]
Output function | range | Output range | resolution | accuracy | remark | ||||||
DC voltage DCV |
100mV | -10.000~110.000mV | 1μV | 0.01+0.01 | Max output current 0.5mA | ||||||
1V | -0.10000~1.10000V | 10μV | 0.01+0.01 | Max output current 2mA | |||||||
10V | -1.0000~11.0000V | 0.1mV | 0.01+0.01 | Max output current 5mA | |||||||
Dc current DCmA |
30mA | 0.000~33.000mA | 1μA | 0.01+0.01 |
In 33mA, the Max load is 1KΩ resistance in simulate transmitter,external power supply 5~28V |
||||||
Ohmn OHM |
400Ω | 0.00~400.00Ω | 0.01Ω | 0.01+0.01 |
simulate current is ±0.05~0.3mA simulate current is ±0.1~0.5mA , plus 0.1Ω additional error wire resistance is excluded in the accuracy |
||||||
4KΩ | 0.0000~4.0000 KΩ | 0.1Ω | 0.01+0.01 |
±0.05~0.3mA simulate current wire resistance is excluded in the accuracy |
|||||||
Thermal couple TC |
R* | 0°C~1767°C | 1°C |
0~100℃ 10~1767℃ 0~100℃ 100~1767℃ |
1.5℃ 1.2℃ 1.5℃ 1.2℃ |
Employ ITS-90 temperature standard
Errors for cold-end compensation is excluded in the accuracy |
|||||
S* | 0°C~1767°C | ||||||||||
K | -200.0°C~1372.0°C | 0.1°C |
-200.0~-100.0℃ -100.0~400.0℃ 400.0~1200.0℃ 1200.0~1372.0℃ |
0.6℃ 0.5℃ 0.7℃ 0.9℃ |
|||||||
E | -200.0°C~1000.0°C |
-200.0~-100.0℃ -100.0~600.0℃ 600.0~1000.0℃ |
0.6℃ 0.5℃ 0.4℃ |
||||||||
J | -200.0°C~1200.0°C |
-200.0~-100.0℃ -100.0~800.0℃ 800.0~1200.0℃ |
0.6℃ 0.5℃ 0.7℃ |
||||||||
T | -250.0°C~400.0°C | -250.0~400.0℃ | 0.6℃ | ||||||||
N | -200.0°C~1300.0°C |
-200.0~-100.0℃ -100.0~900.0℃ 900.0~1300.0℃ |
1.0℃ 0.7℃ 0.8℃ |
||||||||
B* | 600°C~1820°C | 1°C |
600~800℃ 800~1820℃ |
1.5℃ 1.1℃ |
|||||||
L | -200.0°C~900.0°C | 0.1°C |
-200.0~0.0℃ 0.0~900.0℃ |
0.7℃ 0.5℃ |
|||||||
U | -200.0°C~600.0°C | 0.1°C |
-200.0~0.0℃ 0.0~600.0℃ |
0.7℃ 0.5℃ |
|||||||
resistance temperature RTD |
Pt100 385 |
-200.0°C~800.0°C | 0.1°C |
-200.0~0.0℃ 0.0~400.0℃ 400.0~800.0℃ |
0.3℃ 0.5℃ 0.8℃ |
Employ ITS-90 temperature standard
Pt100,Cu50,Cu10 simulate current is: ±0.5~3mA when the simulate current is : ±0.1~0.5mA, add additional 0.5℃ error.
Pt200,Pt500,Pt1000 simulate current is ±0.05~0.3mA wire resistance is excluded in the accuracy |
|||||
Pt200 385 |
-200.0°C~630.0°C |
-200.0~100.0℃ 100.0~300.0℃ 300.0~630.0℃ |
0.8℃ 0.9℃ 1.0℃ |
||||||||
Pt500 385 |
-200.0°C~630.0°C |
-200.0~100.0℃ 100.0~300.0℃ 300.0~630.0℃ |
0.4℃ 0.5℃ 0.7℃ |
||||||||
Pt1000 385 |
-200.0°C~630.0°C |
-200.0~100.0℃ 100.0~300.0℃ 300.0~630.0℃ |
0.2℃ 0.5℃ 0.7℃ |
||||||||
Cu10 | -10.0°C~250.0°C | 1.8℃ | |||||||||
Cu50 | -50.0°C~150.0°C | 0.6℃ | |||||||||
frequency FREQ |
100Hz | 1.00 Hz ~110.00Hz | 0.01Hz | ±2 bytes |
1~11 Vp-p accuracy of square wave level ±5%reading +0.5V 50% duty ratio load >100KΩ |
||||||
1KHz | 0.100 KHz ~1.100KHz | 1Hz | ±2 bytes | ||||||||
10KHz | 1.0KHz~11.0KHz | 0. 1KHz | ±2 bytes | ||||||||
50KHz | 10KHz~50KHz | 2KHz | ±5 bytes | ||||||||
CPM | 60~1200 CPM | 1CPM | ±2CPM | ||||||||
Pulse counting PULSE |
100Hz | 1~100000cycles | 1cyc | ±2 bytes | see related index in frequency | ||||||
1KHz | |||||||||||
10KHz | |||||||||||
Switch volume SWITCH |
100Hz | 1.00Hz~110.00Hz | 0.01Hz | ±2 bytes |
see related index in frequency FET switch Max switch DC voltage/current: +28 V/50mA |
||||||
1KHz | 0.100KHz~1.100KHz | 1Hz | |||||||||
10KHz | 1.0KHz~11.0KHz | 0.1KHz | |||||||||
50KHz | 10KHz~50KHz | 2KHz |
Project | Model Performance parameters |
VICTOR 26 | VICTOR 26H | |
Source | DC millivolt | Range | -5 ~ 110mV | -5 ~ 110mV |
Accuracy= ±(% of the set value+% of range) |
0.01%+0.01% | 0.01%+0.01% | ||
Resolution | 1uV | 1uV | ||
DC voltage | Range | -1 ~ 11V | -1 ~ 11V | |
Accuracy= ±(% of the set value+% of range) |
0.01%+0.01% | 0.01%+0.01% | ||
Resolution | 10uV/0.1mV | 10uV/0.1mV | ||
DC current | Range | 0 ~ 33mA | 0 ~ 33mA | |
Accuracy= ±(% of the set value+% of range) |
0.01%+0.01% | 0.01%+0.01% | ||
Resolution | 1uA | 1uA | ||
Sink current | Range | 0 ~ 33mA | 0 ~ 33mA | |
Accuracy= ±(% of the set value+% of range) |
0.01%+0.01% | 0.01%+0.01% | ||
Resolution | 1uA | 1uA | ||
External power supply |
5 ~ 28V | 5 ~ 28V | ||
Resistance | Range | 0 ~4KΩ | 0 ~4KΩ | |
Accuracy= ±(% of the set value+% of range) |
0.01%+0.01% | 0.01%+0.01% | ||
Resolution | 0.01Ω/0.1Ω | 0.01Ω/0.1Ω | ||
Thermocouple | Range | R/S/K/E/J/T/B/N/L/U | R/S/K/E/J/T/B/N/L/U | |
Accuracy | 0.4℃ | 0.4℃ | ||
Resolution | 0.1℃/1℃ | 0.1℃/1℃ | ||
RTD | Range | Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 |
Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 |
|
Accuracy | 0.2℃ | 0.2℃ | ||
Resolution | 0.1℃ | 0.1℃ | ||
Frequency (Hz) |
Range | 1Hz ~110KHz | 1Hz ~110KHz | |
Accuracy | ±2words | ±2words | ||
Resolution | 0.01Hz/1Hz/0.1KHz/2KHz | 0.01Hz/1Hz/0.1KHz/2KHz | ||
Frequency(CMP) | Range | 60~1200 CPM | 60~1200 CPM | |
Accuracy | ±2words | ±2words | ||
Resolution | 1CPM | 1CPM | ||
Pulse | Frequency | 1Hz ~10KHz | 1Hz ~10KHz | |
Range | 1 ~100000cyc | 1 ~100000cyc | ||
Accuracy | ±2words | ±2words | ||
Resolution | 1cyc | 1cyc | ||
Switch | Range | 1Hz ~110KHz | 1Hz ~110KHz | |
Accuracy | ±2 | ±2 | ||
Resolution | 0.01Hz/1Hz/0.1KHz/2KHz | 0.01Hz/1Hz/0.1KHz/2KHz | ||
Pressure | Range | Depends on the pressure module | Depends on the pressure module | |
Accuracy= ±(% of the set value+% of range) |
Depends on the pressure module | Depends on the pressure module | ||
Resolution | 5 digit display | 5 digit display | ||
Measurement | DC millivolt | Range | -5 ~ 550mV | -5 ~ 550mV |
Accuracy= ±( % of Reading+ % of Range) |
0.01%+0.01% | 0.01%+0.01% | ||
Resolution | 1uV/10uV | 1uV/10uV | ||
DC voltage | Range | -0.5 ~ 35V | -0.5 ~ 35V | |
Accuracy= ±( % of Reading+ % of Range) |
0.01%+0.01% | 0.01%+0.01% | ||
Resolution | 0.1mV/1mV | 0.1mV/1mV | ||
DC current | Range | -5 ~ 55mA | -5 ~ 55mA | |
Accuracy ±( % of Reading+ % of Range) |
0.01%+0.01% | 0.01%+0.01% | ||
Resolution | 1uA | 1uA | ||
Resistance | Range | 0 ~5.5KΩ | 0 ~5.5KΩ | |
Accuracy= ±( % of Reading+ % of Range) |
0.01%+0.01% | 0.01%+0.01% | ||
Resolution | 0.01Ω/0.1Ω | 0.01Ω/0.1Ω | ||
Thermocouple | Range | R/S/K/E/J/T/B/N/L/U | R/S/K/E/J/T/B/N/L/U | |
Accuracy | 0.7℃ | 0.7℃ | ||
Resolution | 0.1℃/1℃ | 0.1℃/1℃ | ||
RTD | Range | Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 |
Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 |
|
Accuracy | 0.4℃ | 0.4℃ | ||
Resolution | 0.1℃ | 0.1℃ | ||
Frequency (Hz) |
Range | 3Hz ~50KHz | 3Hz ~50KHz | |
Accuracy | ±2words | ±2words | ||
Resolution | 0.01Hz | 0.01Hz | ||
Frequency(CMP) | Range | 180~3000000 CPM | 180~3000000 CPM | |
Accuracy | ±2words | ±2words | ||
Resolution | 1CPM | 1CPM | ||
Switch | Range | CLOSE/OPEN | CLOSE/OPEN | |
Threshold | 200 ~300Ω | 200 ~300Ω | ||
Pressure | Range | Depends on the pressure module | Depends on the pressure module | |
Accuracy= ±( % of Reading+ % of Range) |
Depends on the pressure module | Depends on the pressure module | ||
Resolution | 5 digit display | 5 digit display | ||
Continuity beeper | Range | 0 ~500Ω | 0 ~500Ω | |
Accuracy | ≤50Ωsound | ≤50Ωsound | ||
Resolution | 0.01Ω | 0.01Ω | ||
Loop power supply | Range | 24V | 24V | |
Accuracy | ±10% | ±10% | ||
The maximum current | 22mA | 22mA | ||
HART | × | √ | ||
Other functions |
Backlight | √ | √ | |
Auto Power-off | √ | √ | ||
Charging function | √ | √ | ||
Room temperature display | √ | √ | ||
Battery detection | √ | √ | ||
The ramp signal | √ | √ | ||
Communication function | RS232 serial communication, can realize remote control instrument by the device driver software. | RS232 serial communication, can realize remote control instrument by the device driver software. | ||
Characteristic | ||||
Safety | EN61010-1:2001 | EN61010-1:2001 | ||
Withstand voltage | The input and output AC350V/1 minutes | The input and output AC350V/1 minutes | ||
Insulation | The input and output DC500V /50MΩ. | The input and output DC500V /50MΩ. | ||
EMC | EN61326-1:2006 | EN61326-1:2006 | ||
Authentication | CE | CE | ||
Display | 3.2“ TFT screen | 3.2“ TFT screen | ||
Power supply | 4×1.5V AA Alkaline battery | 4×1.5V AA Alkaline battery | ||
Size | 206 × 97 × 60 mm | 206 × 97 × 60 mm | ||
Weight | about 633g | about 633g | ||
Standard Quantity Per Carton | 6pcs | 6pcs | ||
Standard Carton Measurement | 530mm*405mm*310mm | 530mm*405mm*310mm | ||
Standard Carton Cross Weight | 12.6kg | 12.6kg |
Contact Person: Mrs. sales
Tel: +86 13924679853
Fax: 86-755-82268753-262