Product Details:
|
Color: | Blue Or Orange And Black | Size: | 180*90*47mm |
---|---|---|---|
Product Name: | Temperature Source | Model No.: | VICTOR 02+ |
Material: | Plastic, Metal, Silica Gel | Packing Details: | 10pcs/Carton; Carton Size: 39.5*38.5*26cm |
Accuracy: | 0.05% Accuracy | Weight: | Approx. 900 G (including Batteries) |
Power Supply: | 2*1.5V AA Alkaline Battery | ||
High Light: | R Thermocouple Multifunction Process Calibrator,K Thermocouple Multifunction Process Calibrator,R Thermocouple multifunction calibrator |
VICTOR 02+ Thermocouple Calibrator Imput And Output Source 8 Types Of Thermocouple Measurement (R/S/K/E/J/T/B/N)
VC02+THERMOCOUPLE CALIBRATOR
Output and measurement with basic accuracy of 0.05%. 5 digits display for measured value. With resolution of 0.1℃ the output unit can be converted between ℃ and ℉.
Measurements: DC voltage, 8 types of thermocouple measurement (R/S/K/E/J/T/B/N).
Outputs: DC voltage, 8 types of thermocouple outputs (R/S/K/E/J/T/B/N).
Temperature compensation with high accuracy at the cold terminal is designed for measurement and output of thermocouple.
The phase compensation of output make it possible for instrument to drive a load with capacitance up to 2000µf, matching for application with the filter of large capacitance at the input terminal.
Adjustable output gain, easy in operation.
Built-in self-tests with closed-case calibration (no internal calibration adjustment).
Output function and technical index
Output |
Range |
Output range |
Resolution |
Accuracy |
Illustration |
DCV |
100mV |
-10.00~110.00mV |
0.01mV |
0.05%+30uV |
Max. output current ±2mA |
1V |
-0.1000~1.1000V |
0.1mV |
0.05%+0.3mV |
||
TC |
R |
-40~1760℃ |
1℃ |
0.05%+3(less than or equals to 100°C) 0.05%+2(more than 100°C) |
Employs ITS-90 temperature standard The accuracy does not include the error of interior temperature compensation sensor The accuracy does not include the impact of interior thermoelectric force |
S |
-20~1760℃ |
1℃ |
|||
RTD |
B |
400~1800℃ |
1℃ |
0.05%+3(less than or equals to 600°C) 0.05%+2(more than 600°C) |
|
E |
-200.0~1000.0℃ |
0.1℃ |
0.05%+20(less than or equals to -100°C) 0.05%+10(more than -100°C) |
||
K |
-200.0~1370℃ |
0.1℃ |
|||
J |
-200.0~1200.0℃ |
0.1℃ |
|||
T |
-200.0~400.0℃ |
0.1℃ |
|||
N |
-200.0~1300.0℃ |
0.1℃ |
Input function and technical index
Input |
Range |
Output range |
Resolution |
Accuracy |
Illustration |
DC voltage DCmV |
100mV |
-10.00~110.00mV |
0.01mV |
0.05%+3 |
Input resistance:1MΩ |
thermocouple TC |
R |
-40°C~1760°C |
1°C |
0.05%+3(less than or equals to 100°C) 0.05%+2(more than 100°C) |
Input resistance :1MΩ Employs ITS-90 temperature standard The accuracy does not include the error of interior temperature compensation sensor The accuracy does not include the impact of interior thermoelectric force |
S |
-200°C~1760°C |
||||
B |
400°C~1800°C |
0.05%+3(less than or equals to 600°C) 0.05%+2(more than 600°C) |
|||
K |
-200.0°C~1370.0°C |
0.1°C |
0.05%+20(less than or equals to -100°C) 0.05%+10(more than -100°C) |
||
E |
-200.0°C~1000.0°C |
||||
J |
-200.0°C~1200.0°C |
||||
T |
-200.0°C~400.0°C |
||||
N |
-200.0°C~1300.0°C |
General feature
|
: |
two 1.5V alkaline batteries(LR6) |
l power consumption |
: |
about 50m/3V |
|
: |
30V(within terminals or between terminal and earth ground) |
|
: |
0°C~50°C |
|
: |
≤ 80%RH |
|
: |
≤ - 10°C~55°C |
|
: |
≤ 90%RH |
|
: |
0.1×(dedicated accuracy)%/℃(5℃~18℃,28℃~40℃) |
|
: |
180(L)×90(W)×47(D)mm(with protector) |
|
: |
about 500g |
|
: |
User’s Manual, industrial testing lead CF-36 (clips for probe) |
|
: |
complies with IEC1010 (safety standard issued by International Electrician Committee) |