Product Details:
|
Color: | Black And Orange | Weight: | Approx 105g |
---|---|---|---|
Packing: | Blister+cardboard | Product Size: | 143mm×93mm×37mm (L×W×H) |
Accurancy: | ±2.0℃ Or ±2% ( Or ±3.0℃ At 0℃-25℃), Whichever Is Bigger | Emissivity: | 0.95 |
Measuring Time: | ≤0.5s | ||
High Light: | 0.5s Handheld Infrared Thermometer,VICTOR 302B,0.5s portable infrared thermometer |
VICTOR302B Infrared thermometer with Range -32℃~3800℃ Handheld thermometer
I. Brief Introduction to the Product
The instrument is a professional hand-held non-contact infrared thermometer, and is featured by convenient use, strict design, high measurement accuracy, broad temperature measurement range, and with HEIMANN infrared temperature probe, the product has high measuring precision and more stable performance etc. It has the functions like laser aiming, LCD backlight, over-temperature alarm and automatic shutdown. When being used, the product can measure the temperature of objects quickly and accurately only with the probing window aiming at objects.
II. Basic Operating Principles
All objects whose temperature is higher than absolute zero degree will transmit a certain proportion of infrared radiation energy according to their own temperature. The size and wavelength-based distribution of radiation energy have very close relationship with its surface temperature. According to this theory, we may obtain the accurate temperature of a measured object by accurately measuring its infrared transmission energy.
III. Main Technical Indexes
IV. Application Method
1. In order to obtain precise temperature value, the thermometer shall be used 10min after mounting of battery; if the product is moved to a new environment (new place), it shall also be used after 10min.
2. After the detection window is made aiming at the measured object, and the measuring key on the handle is moved, the thermometer will be started automatically. When sending out the prompt sound “beep”, the product will display the measured result.
Note: Before measurement, the emissivity of the object to be measured shall be selected, and meanwhile, the measuring distance shall be adjusted according to the size of the object to be measured.
VICTOR 302B | |
Measurement Range | -32-380℃ |
Distance spot ratio | 12:1 |
Accuracy | ±2℃ or ±2% |
Repetition | 1℃±1% or ±1℃ |
Emissivity | 0.95 |
Resolution | 0.1℃/℉ |
Response time | 500ms 95%response |
Wave length | 8-14μm |
Max./Min./AVG/D-value | √ |
H/L temperature alarm setting | √ |
Data storage | √ |
℃/℉ selection | √ |
Data Display | √ |
Laser target pointer ON/OFF selection |
√ |
LCD backlight ON/OFF selection |
√ |
Auto power off | √ |
Power Supply | 9V battery |
Contact Person: Mrs. sales
Tel: +86 13924679853
Fax: 86-755-82268753-262