Product Details:
|
Color: | Blue And Black | Size: | 205*92*45mm |
---|---|---|---|
Product Name: | Multi-function True RMS Multimeter | Model No.: | VICTOR 98A+ |
Material: | Plastic, Metal, Silica Gel | Packing Details: | 10pcs/Carton; Carton Size: 39.5*38.5*26cm |
Accuracy: | 0.5% Accuracy | Warranty: | 1 Year |
Weight: | Approx. 500 G (including Batteries) | Display: | 22000 Words |
High Light: | VICTOR 98A Multimeter,True RMS VICTOR Digital Multimeter,1kHz VICTOR Digital Multimeter |
VICTOR 98A+ VICTOR Digital Multimeter With AC Hz Peak Measurement
VICTOR 98A+ 4 1/2 22000 Words Multifunctio Multimete Accuracy Of 0.05% With AC Hz Peak Measurement True RMS Bar Graph 1KHz Bandwidth
General Characters
1, 4-1 / 2 bit resolution, display 22000 words, DC voltage accuracy of 0.05%;
2, The measurement function:
* AC voltage, DC voltage, AC current, DC current, resistance, capacitance
* On / off, diode, frequency / duty cycle measurement
* Temperature measurement, thermal resistance measurement, peak measurement (PEAK)
* AC + DC measurement (AC + DC), AC + frequency (AC + Hz) measurement
* Relative value measurement (REL_%), maximum value, minimum value, average value measurement (MAX / MIN / AVG)
3, The display rate: 2.5 to 3 times / second, analog bar refresh rate: 20 ~ 24 times / sec.
4, The AC of true RMS measurement, measurement bandwidth: 20Hz ~ 1kHz.
5, Can choose manual or automatic range measurement.
6, The Display of measurement data hold (DIS_HOLD) and automatic hold (AUTO_HOLD) function.
7, Peak measurement function, 1ms peak sampling capture, can capture spikes pulse.
8, Can choose 1 ~ 24000 reference impedance decibel measurement.
9, Thermocouple measurement: K indexing, built-in temperature sensor, automatic cold junction compensation, can be ° C or ° F temperature display.
10, Large-screen multi-data display, which can display the measured value and other related measurement information
11, Multi-data parameter recording function: manual recording, regular recording, and easy to query the record data.
12, The instrument built-in large-capacity data storage, can store up to 1000 (group) field measurement data.
Can record data, or send to the user PC.
13, Instrument online communication function
* The instrument communicates with the PC using an isolated serial communication module compatible with the USB interface.
* Support industry standard SCPI command, through the device driver software to achieve remote control of the instrument.
Through the powerful, friendly man-machine interface, users can easily access the instrument in a number of data parameters
* Data storage, processing, management, etc., to obtain the data in the form of graphics or forms.
14 Large screen LCD display, with white LED backlight. Simple man-machine operation, compact, rugged for field use.
Technical Data
Project | VICTOR 98A+ | |
DC voltage | Range | 200mV/2V/20V/200V/1000V |
Basic accuracy | ±(0.05%+10) | |
AC voltage | Range | 200mV/2V/20V/200V/1000V |
Basic accuracy | ±(0.5%+40) | |
DC current | Range | 200uA/2000uA/20mA/200mA/2A/10A |
Basic accuracy | ±(0.2%+10) | |
AC current | Range | 200uA/2000uA/20mA/200mA/2A/10A |
Basic accuracy | ±(0.8%+30) | |
Resistance | Range | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ/60MΩ |
Basic accuracy | ±(0.2%+5) | |
Capacitance | Range | 10nF/100nF/1000nF/10uF/100uF /1000uF/10mF/100mF |
Basic accuracy | ±(5%+5) | |
Frequency | Range | 10Hz~10MHz |
Basic accuracy | ±(0.02%+4) | |
Thermocouple | Range | K indexing:-200.0°C~1372.0°C |
Basic accuracy | ±(0.5%+3°C) | |
RTD | Range | Pt100:-200.0°C~800.0°C |
Basic accuracy | ±(0.5%+3°C) | |
Display words | 22000 | |
The measurement rate | 3 times / sec | |
Analog Bar graph | 20 times / sec | |
Automatic / manual range | √ | |
Measure the true effective value | √ | |
Bandwidth | 1kHz | |
The duty ratio | 10%~90% | |
Diode test | √ | |
Continuity beeper | √ | |
dBm | √ | |
AC+DC | √ | |
MAX/MIN/AVG | √ | |
Relative value measurement | √ | |
Data Hold | √ | |
Auto Hold | √ | |
Peak Hold | √ | |
The reference junction compensation | √ | |
°C/ ° F conversion | √ | |
Input impedance | 10MΩ | |
Data recording | 1000 group | |
Online communication | The isolation of the USB interface and PC communication. | |
Support the SCPI command, can realize remote control instrument by the device driver software. The powerful function, friendly man-machine interface, the user can conveniently obtain multiple data parameters of instrument, and the data storage, processing, management, access to data is displayed in the graphical or tabular form. | ||
Auto power-off | √ | |
Display type | LCD | |
Backlight | √ | |
Power Supply | 4×AAA Alkaline batteries | |
Safety | CAT III 600V,CAT II 1000V | |
Electromagnetic compatibility | IEC61326-1,Group2,Class B | |
Size | 205×95×42mm(Sheathing) | |
Weight | About500g | |
Standard Quantity Per Carton | 10pcs | |
Standard Carton Measurement | 395mm*385mm*260mm | |
Standard Carton Cross Weight | 9.8Kg |
Contact Person: Mrs. sales
Tel: +86 13924679853
Fax: 86-755-82268753-262