Product Details:
|
Color: | Black And Orange | Weight: | Approx 170g |
---|---|---|---|
Packing: | Color Box | Hold: | Data Hold |
Sampling Rate: | 3 Times/s | Operation Way: | Manual Range |
Clamp Size: | 30 Mm | Battery: | 9V(6FF2) |
High Light: | 3218A Digital Clamp Multimeter,Automatic Range Digital Clamp Multimeter,AC DC multimeter digital auto range |
3218A Digital Clamp Multimeter Automatic Range For AC DC Current
VICTOR DM3218A Digital Clamp Multimeter 3218A Manual Range Multimeter AC Clamp Meter LCD display with 50mm clamp jaw
1. Introduction
Welcome to choose this product!
The series are a kind of 3 1/2 bit portable digital Clamp-Shape meter, with manual range and automatic range, which may measure AC & DC current and voltage, resistance, test for connection and disconnection, positive voltage on diode, temperature, frequency, phase sequence etc.. It can intelligently be zero at DC current range so long as it is turned on. In general, the zero button needn’t be pressed. The meter is equipped in 1100V surge dischargers, which can more effectively protect the meter. The meter is the ideal tool of the industries of electricity, electronics and refrigeration due to wonderful structure, easily operated, more portable.
2. Safety
The meter is designed in accordance with the safety requirements of the standard IEC1010-1. Please Carefully read this manual before operate it.
2.1 Note for safety symbols:
Warning hint, Caution!
Danger by high-voltage shock!
Double insulation protection
2.2 During measuring, any range may not exceed its input value in Max
2.3 At resistance range, not allowed to impose voltage on input
2.4 During measuring, to prevent the meter from damage, do not turn its round switch to change its range.
2.5 Over DC60V or AC30V may be shock danger, carefully operating during measuring.
2.6 During clamping non-insulation wire, must specially be careful to avoid
2.7 During measuring current, fingers must be placed on the back of the armguard of the meter.
2.8 The meter shall avoid straight sunlight, high temperature and humidity.
2.9 After measuring end, the turning switch shall be at OFF.
2.10 Idling for long term, its batteries shall be taken out to prevent the batteries from leaking liquid to damage parts.
3. Features
3.1 Displaying mode: LCD displayer
3.2 Maximum display: 1999(3 1/2bit)
3.3 Maximum open: 30mm
3.4 Automatic negative indication: Displaying “-“
3.5 Low battery indication
3.6 Operating environment: 0℃~40℃,70%RH(Max.)
3.7 Storage environment: -20℃~60℃,85%RH(Max.)
3.8 Power supply: 9v battery (IEC6F22, NEDA1604, JIS006P or equivalent types), automatic range Clamp-Shape meter AAA type two 1.5v batteries.
3.9 Automatically power off (automatic range): The meter shall automatically be switched off (sleeping state) to save energy without range changed within 15 minutes after switching on. To cancel the function on automatically power off, only as switch on the meter, press HOLD button, then the function is cancelled. Under the function, press the effective switches of the function (panel instruction) or turn the turnplate, the meter shall automatically be switched on.
3.10 buzzer
Automatic range is chosen at any measuring range (2A/20A exception) pressing any function button which normally works, then the buzzer shall make sound once, if the function button doesn’t normally work, the buzzer is mute. The buzzer shall make sound for five times for warning.
3.11 Size 213(Length)375(Width)332(Height)mm
3.12 Weight: about 240gram(with batteries)
4. Technical Data
Basic Function | Range | DM3218+ | DM3218A |
DC Voltage | 500V | ±(1.2%+5) | |
200mV/2V/20V/200V/600V | ±(0.5%+3) | ||
AC Voltage | 500V | ±(1.5%+5) | |
2V/20V/200V/600V | ±(0.8%+5) | ||
DC Current | 200uA/2000uA/20mA/200mA | ±(1.2%+3) | |
AC Current | 2000mA/20A/200A/600A | ±(3.0%+10) | |
200uA/2000uA /20mA/200mA | ±(1.8%+3) | ||
2A/20A/200A/500A | ±(2.5%+5) | ||
Resistance | 200kΩ | ±(1.5%+5) | |
200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ | ±(1.0%+2) | ||
Special Function | DM3218+ | DM3218A | |
Diode test | √ | ||
On-off alarm | √ | ||
Low battery indication | √ | √ | |
Hold | Peak Value Hold | Data Hold | |
Auto power off | √ | √ | |
Lamp | √ | ||
Function protection | √ | √ | |
Input impedance | 10MΩ | 10MΩ | |
Sampling rate | 3 times/s | 3 times/s | |
AC frequency response | 50-60Hz | 50-60Hz | |
Operation way | Manual/Auto range | Manual range | |
Max. Display | 1999 | 1999 | |
Clamp Size | 30mm | 30mm | |
Battery | 3V(1.5V*2) | 3V(1.5V*2) |
5. General Characters
Product Color | Case: black ; Holster color: orange |
Standard Accessories | Test leads , battery ,instruction manual |
Standard inner packing | Color box |
Contact Person: Mrs. sales
Tel: +86 13924679853
Fax: 86-755-82268753-262