Product Details:
|
Color: | Blue Or Orange And Black | Size: | 205 × 95 × 42 Mm |
---|---|---|---|
Product Name: | Process Calibrator | Model No.: | VICTOR 25 |
Packing Details: | 10pcs/Carton; Carton Size: 39.5*38.5*26cm | Accuracy: | 0.02% Accuracy |
Weight: | Approx. 500 G (including Batteries) | Power Supply: | 4*1.5V AAA Alkaline Battery |
High Light: | 0.02% Accuracy Multifunction Process Calibrator,VICTOR 25 Process Calibrator,handheld Multifunction Process Calibrator |
0.02% Accuracy Multifunction Process Calibrator Two Independent Channels
VICTOR 25 Multifunction Process Calibrator Can Be Use Pressure Mould 0.02% Accuracy Two Independent Channels for Input and Output
Introduction
This multifunction process calibrator (the calibrator in the following) is a handheld, battery-operated instrument that measures and sources electrical and physical parameters. (See Table 1)
Table 1 Source and Measurement Function
Measurement Function Sourcing Function |
DCV |
DCI |
OHM |
FREQ |
TC |
RTD |
PRESSURE |
SWITCH |
CONT. |
||
LOOP OFF |
LOOP ON |
||||||||||
DCV |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
DCI |
RAMP ON |
× |
× |
× |
× |
× |
× |
× |
× |
× |
× |
RAMP OFF |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
OHM |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
FREQ |
● |
● |
● |
● |
× |
● |
● |
× |
● |
● |
|
PULSE |
● |
● |
● |
● |
× |
● |
● |
× |
● |
● |
|
SWITCH |
● |
● |
● |
● |
× |
● |
● |
× |
● |
● |
|
TC |
● |
● |
● |
● |
● |
× |
× |
● |
● |
● |
|
RTD |
● |
● |
● |
● |
● |
× |
× |
● |
● |
● |
|
PRESSURE |
● |
● |
● |
● |
× |
● |
● |
× |
● |
● |
|
Note:● indicating simultaneous use is allowed × indicating simultaneous use is not allowed |
Except the functions listed in Table 1, the calibrator has the following features as well:
You can operate the measurement and source function simultaneously. The LCD screen is divided into two separate districts, whose upper part displays measurement information and lower part displays source information.
TC measurement/source terminals and built-in lead connector of same temperature (RJ compensation with auto-reference joint point)
Manual step source and auto -step and sweeping –step source
Room temperature monitoring under any operation
Measurement/source temperature monitoring function
Measurement/source mA% display
Measurement wave-filter function
Measurement manual-holding function
Pressure source auto-holding function
Standard Accessories
Make sure that the package contains all the accessories listed below. And if you find they are damaged or any of them is missing, please contact the vendor from which you purchased the product as soon as possible. Refer to the replaceable optional accessories list in 15.3 in the Manual if you want to replace the parts or optional accessories.
Two set of Industrial testing Lead (CL727220)
A set of Testing Lead (Tp727110)
A set of Alligator clip (CC807130)
A Thermocouple Convertor (TTK07210)
A quick reference guide
A User's Manual
One Fuse 50mA/250V
One Fuse 63mA/250V
Techincal Data
Project |
Model |
VICTOR 24 |
VICTOR 25 |
|
Source |
DC millivolt |
Range |
-10 ~ 110mV |
-10 ~ 110mV |
Accuracy= |
0.02%+0.01% |
0.02%+0.01% |
||
Resolution |
1uV |
1uV |
||
DC voltage |
Range |
-0.1 ~ 11V |
-0.1 ~ 11V |
|
Accuracy= |
0.02%+0.01% |
0.02%+0.01% |
||
Resolution |
10uV/0.1mV |
10uV/0.1mV |
||
DC current |
Range |
0 ~ 22mA |
0 ~ 22mA |
|
Accuracy= |
0.02%+0.02% |
0.02%+0.02% |
||
Resolution |
1uA |
1uA |
||
Sink current |
Range |
0 ~ 22mA |
0 ~ 22mA |
|
Accuracy= |
0.02%+0.02% |
0.02%+0.02% |
||
Resolution |
1uA |
1uA |
||
External power |
5 ~ 28V |
5 ~ 28V |
||
Resistance |
Range |
0 ~40KΩ |
0 ~40KΩ |
|
Accuracy= |
0.02%+0.02% |
0.02%+0.02% |
||
Resolution |
0.01Ω/0.1Ω/1Ω |
0.01Ω/0.1Ω/1Ω |
||
Thermocouple |
Range |
R/S/K/E/J/T/B/N |
R/S/K/E/J/T/B/N |
|
Accuracy |
0.4℃ |
0.4℃ |
||
Resolution |
0.1℃/1℃ |
0.1℃/1℃ |
||
RTD |
Range |
Pt100/Pt200/Pt500/ |
Pt100/Pt200/Pt500/ |
|
Accuracy |
0.2℃ |
0.2℃ |
||
Resolution |
0.1℃ |
0.1℃ |
||
Frequency |
Range |
1Hz ~110KHz |
1Hz ~110KHz |
|
Accuracy |
±2words |
±2words |
||
Resolution |
0.01Hz/1Hz/0.1KHz/2KHz |
0.01Hz/1Hz/0.1KHz/2KHz |
||
Pulse |
Frequency |
N/A |
1Hz ~10KHz |
|
Range |
1 ~100000cyc |
|||
Accuracy |
±2words |
|||
Resolution |
1cyc |
|||
Switch |
Range |
N/A |
1Hz ~110KHz |
|
Accuracy |
±2words |
|||
Resolution |
0.01Hz/1Hz/0.1KHz/2KHz |
|||
Pressure |
Range |
N/A |
Depends on the pressure module |
|
Accuracy= |
Depends on the pressure module |
|||
Resolution |
5 digit display |
|||
Measure |
DC millivolt |
Range |
-5 ~ 550mV |
-5 ~ 550mV |
Accuracy= |
0.02%+0.01% |
0.02%+0.01% |
||
Resolution |
1uV/10uV |
1uV/10uV |
||
DC voltage |
Range |
-0.5 ~ 55V |
-0.5 ~ 55V |
|
Accuracy= |
0.02%+0.01% |
0.02%+0.01% |
||
Resolution |
0.1mV/1mV |
0.1mV/1mV |
||
DC current |
Range |
-5 ~ 55mA |
-5 ~ 55mA |
|
Accuracy= |
0.02%+0.01% |
0.02%+0.01% |
||
Resolution |
1uA |
1uA |
||
Resistance |
Range |
0 ~5.5KΩ |
0 ~5.5KΩ |
|
Accuracy= |
0.05%+0.02% |
0.05%+0.02% |
||
Resolution |
0.01Ω/0.1Ω |
0.01Ω/0.1Ω |
||
Thermocouple |
Range |
R/S/K/E/J/T/B/N |
R/S/K/E/J/T/B/N |
|
Accuracy |
0.7℃ |
0.7℃ |
||
Resolution |
0.1℃/1℃ |
0.1℃/1℃ |
||
RTD |
Range |
Pt100/Pt200/Pt500/ |
Pt100/Pt200/Pt500/ |
|
Accuracy |
0.3℃ |
0.3℃ |
||
Resolution |
0.1℃ |
0.1℃ |
||
Frequency |
Range |
3 Hz~50KHz |
3 Hz~50KHz |
|
Accuracy |
±2words |
±2words |
||
Resolution |
0.01Hz/0.1Hz/1Hz |
0.01Hz/0.1Hz/1Hz |
||
Switch |
Range |
N/A |
CLOSE/OPEN |
|
Threshold |
200 ~300Ω |
|||
Pressure |
Range |
N/A |
Depends on the pressure module |
|
Accuracy= |
Depends on the pressure module |
|||
Resolution |
5 digit display |
|||
Continuity beeper |
Range |
0 ~500Ω |
0 ~500Ω |
|
Accuracy |
≤50Ωsound |
≤50Ωsound |
||
Resolution |
0.01Ω |
0.01Ω |
||
Loop power supply |
Range |
24V |
24V |
|
Accuracy |
±10% |
±10% |
||
The maximum current |
22mA |
22mA |
||
Other functions |
Backlight |
√ |
√ |
|
Auto Power-off |
√ |
√ |
||
Charging function |
√ |
√ |
||
Room temperature display |
√ |
√ |
||
Battery detection |
√ |
√ |
||
The ramp signal |
√ |
√ |
||
Communication function |
RS232 serial communication, can realize remote control instrument by the device driver software. |
RS232 serial communication, can realize remote control instrument by the device driver software. |
||
Characteristic |
||||
Safety |
EN61010-1:2001 |
EN61010-1:2001 |
||
Withstand voltage |
The input and output AC350V/1 minutes |
The input and output AC350V/1 minutes |
||
Insulation |
The input and output DC500V /50MΩ. |
The input and output DC500V /50MΩ. |
||
EMC |
EN61326-1:2006 |
EN61326-1:2006 |
||
Authentication |
CE |
CE |
||
Display |
Double display on the LCD screen |
Double display on the LCD screen |
||
Power supply |
4×1.5V AAA Alkaline battery |
4×1.5V AAA Alkaline battery |
||
Size |
205 × 95 × 42 mm |
205 × 95 × 42 mm |
||
Weight |
About 500g |
About 500g |
||
Standard Quantity Per Carton |
10pcs |
10pcs |
||
Standard Carton Measurement |
395mm*385mm*260mm |
395mm*385mm*260mm |
||
Standard Carton Cross Weight |
12.4Kg |
12.4Kg |
Contact Person: Mrs. sales
Tel: +86 13924679853
Fax: 86-755-82268753-262