Product Details:
|
Color: | Black And Orange | Weight: | Approx 250g |
---|---|---|---|
Packing: | Color Box | Hold: | Data Hold |
Product Size: | 198×73×37mm | Operation Way: | Auto Range |
Clamp Size: | 30 Mm | Battery: | 1.5V*2 |
High Light: | Pocket DC AC Clamp Meter,600V DC AC Clamp Meter,Commercial Electric 600a Ac Digital Clamp Meter |
Commercial Electric 600a Ac Digital Clamp Meter Pocket DC 600V 20MΩ 1000uF
2000 Counts Pocket DC AC Clamp Meter 600V 600A 20MΩ 1000uF
VICTOR 606A Multimeter 2000 Counts Pocket Clamp Digital Multimeter 3 1/2 Large LCD Display 600V 600A 20MΩ 1000uF
1. SUMMARIZE
This meter is a handheld automatic range digital multiemter which driven by battery. It can be used to measure such parameters as DCV, ACV, ACA, Resistance, Continuity Buzzer, Diode, etc.
2. GENERAL FEATURE
Displaying:Max. displaying:2000,
Sampling rate: approx. 3 times/second.
Polarity indication:Automatic negative polarity indication
Over range indication:” OL” shown on the LCD
Low battery indication:“ ” appears
Operation environment:0℃~40℃,R.H.< 75%.
Storage environment:-10℃~50℃,R.H.<80%.
Power supply:(Size AAA battery)1.5V×2
Size:198×73×37mm
Weight:about 250g.
Accessories:user’s manual,battery, probes.
3. Technical Data
Accuracy:±(a%×rdg+d) Temperature:(23±5)℃,R.H.<75%
3-1. ACV(V~)
RANGE | ACCURACY |
2V/20V/200V | ±(0.8%+10d) |
600V | ±(1.0%+10d) |
Input resistance:10MΩ
Frequency response:SIN wave and triangular wave is 40Hz~1kHz, other wave is 40Hz~200Hz
3-2. DCV
RANGE | ACCURACY |
200mV/2V/20V/200V | ±(0.5%+4d) |
600V | ±(1.0%+6d) |
Input resistance:10MΩ
3-3. RESISTANCE(auto range)
RANGE | ACCURACY |
200Ω/2kΩ/20kΩ/200kΩ/2MΩ | ±(1.0%+5d) |
20MΩ | ±(1.2%+10d) |
3-4. ACA A~(auto range)
RANGE | ACCURACY |
2A/20A | ±(2.5%+8d) |
200A/600A | ±(2.5%+8d) |
Frequency response:50~60Hz
3-5. CAPACITANCE (auto range)
RANGE | ACCURACY |
2nF/20nF/200nF/2uF/20uF/1000uF | ±(5.0%+8d) |
FUNCTION | RANGE | 606A | 606B | 606C |
ACV | 2V/20V/200V | ±(0.8%+10) | ||
400mV/4V/40V/400V | ±(0.8%+10) | |||
4V/40V/400V | ±(0.8%+10) | |||
600V | ±(1.0%+10) | ±(1.0%+10) | ±(1.0%+10) | |
DCV | 200mV/2V/20V/200V | ±(0.5%+4) | ||
400mV/4V/40V/400V | ±(0.5%+4) | ±(0.5%+4) | ||
600V | ±(1.0%+6) | ±(1.0%+6) | ±(1.0%+6) | |
RESISTANCE | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ | ±(1.0%+5) | ||
400Ω/4kΩ/40kΩ/400kΩ/4MΩ | ±(1.0%+5) | ±(1.0%+5) | ||
20 MΩ | ±(1.2%+10) | |||
40 MΩ | ±(1.2%+10) | ±(1.2%+10) | ||
ACA | 2A/20A | ±(2.5%+8) | ||
4A/40A | ±(2.5%+8) | |||
40A/600A | ±(2.5%+8) | |||
200A/600A | ±(2.5%+8) | |||
400A/600A | ±(2.5%+8) | |||
CAPACITANCE | 2nF/20nF/200nF/2uF/20uF/1000uF | ±(5.0%+8) | ||
4nF/40nF/400nF/4uF/40uF/1000uF | ±(5.0%+8) | ±(5.0%+8) | ||
FREQUENCY | 0-10MHz | ±(0.3%+3) | ±(0.3%+3) | |
DCA | 40A/600A | ±(2.5%+8) | ||
TEMPERATURE | -20℃~400℃ / -4℉~752℉ | ±(3.0%+2) | ||
DIODE TEST | √ | √ | √ | |
CONTINUITY TEST | √ | √ | √ | |
DATA HOLD | √ | √ | √ | |
LOW BATTERY INDICATE | √ | √ | √ | |
AUTO POWER OFF | √ | √ | √ | |
OVERLOAD PROTECTION | √ | √ | √ |