Product Details:
|
Color: | Blue And Black | Size: | 205*92*45mm |
---|---|---|---|
Product Name: | Process Multimeter | Material: | Plastic, Metal, Silica Gel |
Packing Details: | 10pcs/Carton; Carton Size: 39.5*38.5*26cm | Accuracy: | 0.5% Accuracy |
Warranty: | 1 Year | Weight: | Approx. 500 G (including Batteries) |
VICTOR 79 Digital Multimeter 2 In 1 4-20mA Signal Output Multimeter Process Signal Source 40MΩ RTD RSKEJTNB Cu50 Pt100
Specifications
All the speculations apply to +18℃to +28℃, 10% to 70%RH unless stated otherwise.
All speculations assume a 5- minute warm- up period.
Standard speculation is valid for one year.
DC Voltage Measurement
Range(DC V) | Resolution | Accuracy,+( % of reading +counts) |
4.000V | 0.001V | 0.2%+4 |
40.00V | 0.01V | 0.2%+4 |
400.0V | 0.1V | 0.2%+4 |
Measuring Impedance:10 MΩ(nominal),<100pF Common mode rejection ratio: 50Hz or 60Hz > 100dB Normal mode rejection ratio: 50Hz or 60Hz > 45dB Overvoltage protection: 600Vp-p |
DC mV Measurement
Range(DC mV) | Resolution | Accuracy,+( %reading +counts) |
40.00mV | 0.01 mV | 0.5%+6 |
400.0mV | 0.1 mV | 0.2%+4 |
Measuring Impedance: 10 MΩ(nominal) Overvoltage protection: 600Vp-p |
TC Measurement
Range(type) | Set Range | Resolution | Accuracy+(%reading +counts) |
R | -40~1760℃ | 1℃ |
0.5%+3(≤100℃) 0.5%+2(>100℃) |
S | -20~1760℃ | 1℃ |
0.5%+3(≤100℃) 0.5%+2(>100℃) |
B | 400~1800℃ | 1℃ |
0.5%+3(≤600℃) 0.5%+2(>600℃) |
E | -200~500℃ | 1℃ |
0.5%+2(≤-100℃) 0.5%+1(>-100℃) |
K | -200~950℃ | 1℃ |
0.5%+2(≤-100℃) 0.5%+1(>-100℃) |
J | -200~700℃ | 1℃ |
0.5%+2(≤-100℃) 0.5%+1(>-100℃) |
T | -200~400℃ | 1℃ |
0.5%+2(≤-100℃) 0.5%+1(>-100℃) |
N | -200~1000℃ | 1℃ |
0.5%+2(≤-100℃) 0.5%+1(>-100℃) |
By using ITS-90 temperature scale Note: The accuracy does not include the error of internal temperature compensation caused by a sensor. The range of the internal temperature compensation sensor is + 2℃. |
AC Voltage Measurement
Range(ACV) | Resolution |
Accuracy,+( %reading +counts) 40~400Hz |
400.0mV | 0.1mV | 1.0%+4 |
4.000V | 0.001V | 0.5%+4 |
40.00V | 0.01V | 0.5%+4 |
400.0V | 0.1V | 0.5%+4 |
Specifications are valid from 5% to 100% of amplitude range 400mV is only confined to manual range AC conversion: average value Measuring Impedance: 10 MΩ(nominal),<100pF Common mode rejection ratio: 50Hz or 60Hz > 100dB Overvoltage protection: 600Vp-p |
DC Current Measurement
Range(DC mA) | Resolution | Accuracy,+( %reading +counts) |
40.00mA | 0.01 mA | 0.2%+4 |
400.0 mA | 0.1 mA | 0.2%+4 |
Overload protection: 0.5A,250V fast-blow fuse Measuring Impedance: 1Ω |
AC Current Measurement
Range(AC mA) | Resolution |
Accuracy,+( %reading +counts) 40~400Hz |
40.00mA | 0.01 mA | 0.5%+4 |
400.0 mA | 0.1 mA | 0.5%+4 |
Specifications are valid from 5% to 100% of amplitude range Overload protection: 0.5A,250V fast-blow fuse Measuring Impedance: 1Ω |
Resistance Measurement
Range | Resolution | Accuracy,+( %reading +counts) |
400.0Ω | 0.1Ω | 0.2%+4 |
4.000kΩ | 0.001kΩ | 0.2%+4 |
40.00kΩ | 0.01kΩ | 0.2%+4 |
400.0kΩ | 0.1kΩ | 0.2%+4 |
4.000MΩ | 0.001 MΩ | 0.5%+4 |
40.00 MΩ | 0.01 MΩ | 1%+4 |
Open circuit voltage:0.4v Guide lead resistance is excluded in the accuracy Overvoltage protection: 600Vp-p |
RTD Measurement
Range(type) | Input Range | Resolution | Accuracy,+( %reading +counts) |
Pt100 | -200~700℃ | 1℃ | 0.5%+2 |
Cu50 | -50~150℃ | 1℃ | 0.5%+4 |
By using Pt100-385 temperature scale Measuring current 1 mA Note: attached lead resistance is excluded |
Frequency Count Accuracy
Range | Resolution | Accuracy,+( %reading +counts) |
50.00Hz | 0.01Hz | 0.1%+3 |
500.0Hz | 0.1Hz | 0.1%+3 |
5.000KHz | 1Hz | 0.1%+3 |
50.00KHz | 0.01KHz | 0.1%+3 |
100.0KHz | 0.1KHz | 0.1%+3 |
Display updates 3 times/second (at >10Hz) |
Diode Test and Continuity Test
Diode test indication:
Displays voltage drop across device, open circuit voltage: 1.1v-1.6v; short circuit current:<0.2 mA(typical value). Accuracy+ (2%reading +1count)
Continuity test indication:
Continuous audible tone for test resistance<50
Open circuit voltage: <0.45v
Short circuit current:130μA typical
Overload protection: 600V(peak)
Technical Data
Project | VICTOR 77 | VICTOR 78 | VICTOR 79 | ||
Measurement | DC voltage | Range | ±51V | ±400V | ±400V |
The highest resolution |
10mV | 0.01mV | 0.01mV | ||
Basic accuracy | 0.5% | 0.2% | 0.2% | ||
AC voltage | Range | `510V | 400V | 400V | |
The highest resolution |
100mV | 0.1mV | 0.1mV | ||
Basic accuracy | 1.5% | 0.5% | 0.5% | ||
Resistance | Range | 5kΩ | 40MΩ | 40MΩ | |
The highest resolution |
1Ω | 0.1Ω | 0.1Ω | ||
Basic accuracy | 0.5% | 0.2% | 0.2% | ||
DC current | Range | ±22mA | ±400mA | ±400mA | |
The highest resolution |
1uA | 10uA | 10uA | ||
Basic accuracy | 0.2% | 0.2% | 0.2% | ||
AC current | Range | N/A | 400mA | 400mA | |
The highest resolution |
10uA | 10uA | |||
Basic accuracy | 0.5% | 0.5% | |||
Thermocouple | Range | N/A | N/A | R,S,B,E,K,J,T,N | |
The highest resolution |
1°C | ||||
Basic accuracy | 0.5% | ||||
RTD | Range | N/A | N/A | Cu50,Pt100 | |
The highest resolution |
1°C | ||||
Basic accuracy | 0.5% | ||||
CAP | Range | N/A | N/A | N/A | |
The highest resolution |
|||||
Basic accuracy | |||||
Frequency | N/A | 10Hz~100kHz | 10Hz~100kHz | ||
Diode test | √ | √ | √ | ||
Continuity beeper | √ | √ | √ | ||
Data hold | √ | √ | √ | ||
Relative value measurement | N/A | √ | √ | ||
Source | DC voltage | Range | N/A | -50.0mV~550.0mV -0.500V~5.500V |
-10.00mV~110.00mV -0.5000V~5.5000V |
Resolution | 0.1mV,1mV | 0.01mV,0.1mV | |||
Basic accuracy | 0.2% | 0.2% | |||
Resistance | Range | N/A | N/A | 0~400.0Ω | |
Resolution | 0.1Ω | ||||
Basic accuracy | 0.2% | ||||
DC current | Range | 22mA | 22mA | 22mA | |
Resolution | 0.001mA | 0.01mA | 0.001mA | ||
Basic accuracy | 0.2% | 0.2% | 0.2% | ||
Simulating transmitter | √ | √ | √ | ||
25%,100%Step output | √ | √ | √ | ||
Automatic ramp | N/A | √ | √ | ||
Automatic step | N/A | √ | √ | ||
Display current and % of span | √ | √ | √ | ||
Loop power | 24V | 15V | 15V | ||
Frequency | N/A | 1.0Hz~11.0kHz | 1.0Hz~11.0kHz | ||
Thermocouple | N/A | N/A | R,S,B,E,K,J,T,N | ||
RTD | N/A | N/A | Cu50,Pt100 | ||
Loop detection | The 24V loop power supply and measuring the current | √ | N/A | N/A | |
Built in 250 Ω HART loop resistance |
√ | N/A | N/A | ||
Power Supply | 2×1.5V AA Alkaline battery | 4×1.5V AAA Alkaline battery | 4×1.5V AAA Alkaline battery | ||
Auto Power-off | √ | √ | √ | ||
Backlight | N/A | √ | √ | ||
Safety | CAT Ⅳ 600V, Pollution degree 2 |
CAT Ⅲ 600V , Pollution degree 2 |
CAT Ⅲ 600V, Pollution degree 2 |
||
Size | 180×90×52 | 205×95×42 | 205×95×42 | ||
Weight | About 400g | About 500g | About 500g | ||
Accessories | Test line, manual,fuse | Test line, manual,fuse | Test line, manual,fuse | ||
Standard Quantity Per Carton | 10pcs | 10pcs | 10pcs | ||
Standard Carton Measurement | 395mm*385mm*260mm | 395mm*385mm*260mm | 395mm*385mm*260mm | ||
Standard Carton Cross Weight | 8.8Kg | 9.8Kg | 10.2Kg |
Contact Person: Mrs. sales
Tel: +86 13924679853
Fax: 86-755-82268753-262