Product Details:
|
Size: | 150mm*100mm *38mm | Product Name: | Analog Multimeter |
---|---|---|---|
Model No.: | VC3021 | Product Packing: | Color Box |
Packing Details: | 50pcs/Carton; Carton Size:46.4*31.5*51 | Brand: | VICTOR |
High Light: | Analog VICTOR Digital Multimeter,VC3021,VICTOR Digital Multimeter 1000V |
Large Lcd Display Analog VICTOR Digital Multimeter 1000V 10A 200MΩ
VC3021 Analog Multimeter Large Lcd Display 1000V 10A 200MΩ
SPECIFICATIONS
General specification
Items Specification
Drop shock proof: Taut-band structure is adopted in the meter section. The meter section is designed to withstand shock.
Circuit protection: The circuit is protected by fuse even when voltage of up to AC 230V is impressed on each range for 5 seconds.
Internal battery: R6 (IEC) or UM-3 1.5V×2
Internal fuse: 0.5A/250V 5.2mm dia ×20mm
Standard calibration temp
And humidity range.: 23±2℃ 45-75% RH
Operating temperature and
humidity range.: 0-40℃, 80%RH max. No condensation
Withstand voltage: 3KV AC(1 min) between input terminal and case
Dimensions and weight: 150×100×38mm approx. 300g
Accessories: Instruction manual Test leads.
WARNING
To ensure that the meter is used safely, follow all safety and operating instructions
3. Never apply an input signals exceeding the maximum rating input value .
4. Never use meter for measuring the line connected with equipment (i.e.motors) that generates induced or surge voltage since it may exceed the maximum allowable voltage.
5. Never use meter if the meter or test leads are damaged or broken.
6. Never use uncased meter.
7. Be sure to use a fuse of the specified rating or type. Never use a substitute of the fuse or never made a short circuit of the fuse.
8. Always keep your fingers behind the finger guards on the probe when making measurements.
9. Be sure to disconnect the test pins from the circuit when changing the function or range.
10. Before starting measurement, make sure that the function and range are properly set in accordance with the measurement.
11. Never use meter with wet hands or in a damp environment.
14. To ensure safety and maintain accuracy, calibrate and check the meter at least once a year.
Technical data | |||
Model | 3021 | ||
Full scale value | Accuracy | Remarks | |
DCV | 0.1V | 士5% against fulll scale |
Input inpedance 20kΩ /V |
0.5V/2.5V/10V/50V | 士3% against full scale |
||
250V/1000V | Input inpedance 9kΩ /V |
||
ACV~ | 10V/50V/250V/1000V | 士4% against full scale |
Input inpedance 9kΩ /V |
DCA | 50uA | 士3% against fulll scale |
*1 Voltage drop 0.1V |
2.5mA/25mA/0.25A | *1 Voltage drop 0.18V |
||
10A | * | ||
Ω | 2kΩ 20kΩ/200kΩ/2MΩ (*1Ω/*10Ω/*100Ω*1kΩ) |
士3% of arc | Center value 20Ω Max. Value 2kΩ release Voltage 3V |
200MΩ(*100kΩ) | 士5% of arc | ||
dB | - 10dB~+22dB (10VAC~+62 dB) |
* | Input impedance 9kΩ/V |
LI | 0~ 150mAa*1 range 0~ 15mAat*10 range 0~ 15mAat*1K range 0~ 1.5uAat*100k range |
Current across test pins |
|
hFE | 1000 at * 10 range | * |
Contact Person: Mrs. sales
Tel: +86 13924679853
Fax: 86-755-82268753-262