Product Details:
|
LCD Display: | 3.5 Inch TFT Display | Size: | 265mmx105mmx305mm |
---|---|---|---|
Material: | Plastic, Metal, Silica Gel | Product Name: | Digital LCR Meter |
Model No.: | 4091B | Packing Details: | 6pcs/Carton; Carton Size: 103*45*45cm;20.5KG/Carton |
High Light: | SCPI LCR Digital Meters,20 KHz LCR Digital Meters,20 KHz bench lcr meter |
SCPI LCR Digital Meters 10 Hz 20 KHz Bandwidth Frequency Adjustable
VICTOR 4091B LCR Meter Bench Top 10 Hz ~ 20 KHz bandwidth frequency adjustable 0.2% Accuracy 3.5 inch TFT display Support SCPI
Product description
LCR digital bridge is designed using automatic balance bridge principle component parameter analyzer, the tests of 10 hz ~ 100 KHZ bandwidth, frequency adjustable, 0.2% of the basic classification function provided by the accuracy of measurement and instrument for the vast majority of components and materials to provide accurate and complete the survey and analysis, is widely used in product research and development, components such as incoming inspection, product online applications.
Technical description
Output signal: low effective, open collector output, Opto-couplers isolation.
Input signal: Opto-couplers isolation
DC power supply voltage supported by power pin: 3V-25V.
Product features
DCR measurement accuracy
Range | Display range | Accuracy Re |
100MΩ | 20.00MΩ-99.99MΩ | 10.0%+20 count |
20MΩ | 10.00MΩ-20.00MΩ | 5.0%+10 count |
10MΩ | 4.000MΩ-9.999MΩ | 2.0%+5 count |
4MΩ | 400.0kΩ-3.9999MΩ | 1.2%+3 count |
400kΩ | 40.00kΩ-399.99kΩ | 0.3%+3 count |
40kΩ | 4.000kΩ-39.999kΩ | 0.2%+2 count |
4kΩ | 400.0Ω-3.9999kΩ | 0.1%+2 count |
400Ω | 40.00Ω-399.99Ω | 0.2%+2 count |
40Ω | 4.000Ω-39.999Ω | 0.3%+3 count |
4Ω | 0.400Ω-3.999Ω | 1.0%+5 count |
0.4Ω | 0.000Ω-0.399Ω | 3.0%+10 count |
Model | 4091B | |
Testing frequency |
10~20KHz Continuously adjustable, a step of 1 Hz |
|
Display screen | 3.5” TFT LCD screen | |
Number of display digits |
Principal parameter: 5 digit Secondary parameter: 5 digit |
|
Measured parameter: |
Principal parameter: L/C/R/Z Secondary parameter: X/D/Q/θ/ESR |
|
Measurement range |
L:0.001µH~99999H, C:0.001pF~99.999mF, R:0.0001Ω~99.999MΩ |
|
Basic accuracy | 0.2% | |
Measuring display speed | 2 time/s (slow), 4 times/s (medium), 8 time/s (fast) | |
Internal bias | 0-1500mV adjustable, at a step of 1mV. | |
Testing level | Six fixed level(0.1V,0.3V,0.6V,1V,1.5V,2V) | 0.1~2V adjustable, at a step of 1mV. |
Signal source output impedance | 30Ω,100Ω | |
Calibration function | Open circuit calibration, short circuit calibration | |
Screening function | The limit range of screening can be set to -50%~+50%, and the fixed points are 1%, 5%, 10% and 20%. | |
Comparator | 5 groups sorting,3 groups of qualified setting, one group of unqualified setting, one group of auxiliary setting | |
Interfaces | standard: RS232(or 485), USB Device, Handler ;optional :GPIB,USB Host | |
Others | Support dc resistance (DCR), electrolytic capacitor measurement model,Adjustment of backlight brightness, Chinese and English are optional |