Send Message
Home ProductsDigital Clamp Multimeter

VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight

Certification
China XI'AN BEICHENG ELECTRONICS CO.,LTD certification
China XI'AN BEICHENG ELECTRONICS CO.,LTD certification
Customer Reviews
In general, very satisfied. Packed all on conscience. Thank you to the seller for the prompt answers in the selection of goods. As for the quality of the goods, there is no smell, and there is no feeling of cheap. Everything is done well enough. The call is clear loud.

—— Alexander

Хороший мультиметр с вполне приемлемой точностью и хорошим функционалом. Щупы толстые, мягкие, с низким сопротивлением. Правда сам металлический кончик уж очень маленький - порядка 2мм., как то несколько не удобно. В целом всё хорошо.

—— Maria

Gute Produkte, zuverlässiger Verkäufer, Kundenservice war top , alle meine Fragen wurden schnell beantwortet.würde ich auf jeden Fall weiter empfehlen.

—— Yanik

Excellent multimeter, measures, exactly, current consumption when turning on 1.7ma, in 25mA mode, the build quality is good, the switch of operating modes switches gently. Of the minuses, power is 9V, and piquant when switching

—— Natasha Santiesteban

Perfect multimeter with very good quality. For this price nothing can beat this! 4 days delivery from the order. I am maximally satisfied! Recommended product, recommended seller! Thank you

—— Fernando Rodríguea

I'm Online Chat Now

VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight

VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight

Large Image :  VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight

Product Details:
Place of Origin: CHINA
Brand Name: VICTOR
Certification: CE
Model Number: VICTOR 606+ 606A+ 606B+ 606C+
Payment & Shipping Terms:
Minimum Order Quantity: 300
Price: VICTOR606+ USD9/pc VICTOR606A+ USD10/pc VICTOR606B+ USD11.3/pc VICTOR606C+ USD20/pc
Packaging Details: Color box ,30pcs/Carton ,13KG/Carton
Delivery Time: 5-30 days
Payment Terms: T/T, Western Union, L/C,Paypal
Supply Ability: 10000 pc available

VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight

Description
Color: Black And Orange Weight: Approx 236g
Packing: Color Box Product Size: 207×72×39mm
Operation Way: Auto Range Clamp Size: 30 Mm
Battery: 1.5V*2 Display: 5999 Counts
High Light:

5999 Counts Digital Clamp Meter

,

Live NCV Flashlight Digital Clamp Meter

,

600V 600A Digital Clamp Multimeter

VICTOR 606+ 606A+ 606B+ 606C+ Digital Clamp meter 5999 counts AC/DC 600V 600A Clamp multimeter with Live NCV Flashlight True-RMS function

 
 

1. SUMMARIZE
This meter is a handheld automatic range digital multiemter which driven by battery. It can be used to measure such parameters as DCV, ACV, DCA and ACA, Resistance, Continuity Buzzer, Diode, Frequency etc.
 
2. SAFETY OPERATION RULE
The meter’s design is in accordance with the CE certification, meets the standard of IEC61010. Read the following before operation.
2-1. Input over range is prohibited in each range during the test.
2-2. Place the function knob to the proper range before measurement, in case damage the meter, do not switch the range during measurement.
2-3. Voltage less than 36V is safety voltage. To avoid electric shock, be careful when measuring voltage higher than 36V DC, 25V AC.
2-4. Don’t input voltage under the resistance, capacitance, diode, continuity test, frequency measurement.
 
5. TECHNICAL CHARACTERISTIC

 

FUNCTION 606+ 606A+ 606B+ 606C+ Accuracy
DCV 200mV/2V/20V 600mV/6V/60V 600mV/6V/60V 600mV/6V/60V ±(0.5%+7)
200V 600V 600V 600V ±(1.0%+ 20)
600V / / / ±(1.2%+ 20)
ACV 2V/20V 6V/60V 6V/60V 6V/60V ±(0.8%+ 10)
200V 600V 600V 600V ±(1.2%+ 25)
600V / / / ±(1.5%+25)

LOW INPEDANCE

ACV

2V/20V 6V/60V 6V/60V 6V/60V ±(0.8%+ 10)
200V 300V 300V / ±(1.2%+25)
300V / / / ±(1.5%+ 25)
/ / / 300V ±(1.0%+12)
ACA 2A 6A 6A / ±(4.0%+ 50)
20A 60A 60A / ±(4.0%+ 35)
200A/600A 600A 600A / ±(4.0%+15)
/ / / 60A/600A ±(4.0%+10)
DCA / / / 60A/600A ±(4.0%+10)
RESISTENCE

200Ω/2kΩ/20kΩ/

200kΩ/2MΩ

600Ω/6kΩ/60kΩ/

600kΩ/6MΩ

600Ω/6kΩ/60kΩ/

600kΩ/6MΩ

600Ω/6kΩ/60kΩ/

600kΩ/6MΩ

±(1.0%+ 5)
20MΩ 20MΩ 20MΩ 20MΩ ±(1.5%+15)
/ 60MΩ 60MΩ 60MΩ ±(2.5%+20)
CAPACITANCE / 6nF 6nF 6nF ±(5.0%+40)
/ 60nF/600nF/6uF 60nF/600nF/6uF 60nF/600nF/6uF ±(5.0%+ 10)
/ 60uF/600uF/6mF 60uF/600uF/6mF 60uF/600uF/6mF
FREQUENCY /

10Hz/100Hz/1kHz/10kHz/

100kHz/ 1MHz/10MHz

10Hz/100Hz/1kHz/10kHz/

100kHz/ 1MHz/10MHz

10Hz/100Hz/1kHz/10kHz/

100kHz/ 1MHz/10MHz

±(0.3%+3)
TEMPERATURE / /

-20℃~1000℃

(-4-1832)℉

-20℃~1000℃

(-4-1832)℉

/

 

 

Display method

LCD display

5999 count

Max/Min
Maximum display

5999 count

(606+ 1999count)

Low Z
Diode measurement Working temperature and humidity (0-40) ℃ <75%
Data retention Storage temperature and humidity (-10~50)℃<80%
NCV measurement Automatic shut-down About 15 minutes
Fire detection Over-range display the highest digit displays OL
Low voltage warning Unit symbol
Flashlight lighting Open jaws 35mm
True effective value input resistance 10MΩ
INRUSH 606C+ only Sampling rate 3 times/sec
VFC 606C+ only power supply Two AAA batteries
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 0
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 1
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 2
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 3
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 4
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 5
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 6
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 7
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 8
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 9
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 10
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight 11
 
 
 
 

 

 

 

Contact Details
XI'AN BEICHENG ELECTRONICS CO.,LTD

Contact Person: Mrs. sales

Tel: +86 13924679853

Fax: 86-755-82268753-262

Send your inquiry directly to us (0 / 3000)