Product Details:
|
Color: | Black And White | Material: | ABS+Steel,Plastic |
---|---|---|---|
Product Name: | Bench Top Multimeter | Model No.: | 8246A |
Display: | 55000 Counts | Dimensions: | 245mm X 220mm X 82mm (width X Height X Depth); |
Accuracy: | 0.025% Accuracy | Bandwidth: | 20Hz ~ 50KHz |
High Light: | VFD Bench Type Digital Multimeter,Bench Type Digital Multimeter True RMS,VFD True RMS Digital Multimeter |
VFD Bench Type Digital Multimeter Auto Range True RMS 55000 RS232
VICTOR 8246A Bench Top Digital Multimeter Auto Range True RMS 55000 RS232 DC/AC Cap. Freq.Temperature Test 20Hz ~ 50KHz Bandwidth
GENERALIZATION
The instrument is a 5-digit portable multimeter powered by 220 V dc with high accuracy and performance. It has all the features of a digital millimeter and measures AC /DC voltage, AC/DC current, resistance, capacitance, dBm, TC, RTD, Diode Test, and Continuity Check, frequency/duty cycle ratio. Besides, it has the following features:
A VFD Display that allows two properties of an input signal to be displayed at the same time.
Accurate true rms AC value, bandwidth for type A measurement: 20Hz~50kHz ; bandwidth for type B measurement: 20Hz~1kHz.
1uV sensitivity in volts DC.
2-wired and 4-wired resistance measurement.
Measurable capacity higher than 100mF.
Selectable 1~2400Ω reference impedance dBm measurement.
Display hold, relative data measurement, maximum value, minimum value and average value measurement
Selectable manual or auto-range.
Display rate: 5 readings/ second (slow) and 20 readings/second (slow).
TC measurement: K graduation degree, inner temperature transmitter, auto-cold compensation, and temperature display in ℃ or℉.
The built-in memory counter can store up to 50000 (group) independent measuring data.
Panel calibration function (without open-case adjustment).
Isolation of common Universal Serial Bus(USB) Port and RS232 serial port.
Remote operation, surveillance and recording data with a computer. Standard SCPI command is supported, and remote control of the meter can be realized by equipment software.
Project |
VICTOR 8246A |
VICTOR 8246B |
|
DC voltage |
Range |
50mV/500mV/5V/50V/500V/1000V |
50mV/500mV/5V/50V/500V/1000V |
Basic accuracy |
±(0.025%+5dgt) |
±(0.025%+5dgt) |
|
AC voltage |
Range |
50mV/500mV/5V/50V/500V/750V |
50mV/500mV/5V/50V/500V/750V |
Basic accuracy |
±(0.7%+30dgt) |
±(0.7%+30dgt) |
|
DC current |
Range |
500uA/5000uA/50mA/500mA/5A/10A |
500uA/5000uA/50mA/500mA/5A/10A |
Basic accuracy |
±(0.15%+10dgt) |
±(0.15%+10dgt) |
|
AC current |
Range |
500uA/5000uA/50mA/500mA/5A/10A |
500uA/5000uA/50mA/500mA/5A/10A |
Basic accuracy |
±(0.8%+30dgt) |
±(0.8%+30dgt) |
|
Resistance |
Range |
500Ω/5kΩ/50kΩ/500kΩ /5MΩ/50MΩ |
500Ω/5kΩ/50kΩ/500kΩ /5MΩ/50MΩ |
Basic accuracy |
±(0.05%+5dgt) |
±(0.05%+5dgt) |
|
Capacitance |
Range |
10nF/100nF/1000nF/10uF/100uF |
10nF/100nF/1000nF/10uF/100uF |
Basic accuracy |
±(5%+5dgt) |
±(5%+5dgt) |
|
Frequency |
Range |
10Hz~100kHz |
10Hz~100kHz |
Basic accuracy |
±(0.02%+4dgt) |
±(0.02%+4dgt) |
|
Thermocouple |
Range |
K indexing:-200.0°C~1360.0°C |
K indexing:-200.0°C~1360.0°C |
Basic accuracy |
±(0.5%+0.5°C) |
±(0.5%+0.5°C) |
|
RTD |
Range |
Pt100:-200.0°C~850.0°C |
Pt100:-200.0°C~850.0°C |
Basic accuracy |
±(0.5%+0.5°C) |
±(0.5%+0.5°C) |
|
Display words |
55000 |
55000 |
|
The measurement rate |
Quick: 20 times / sec |
Quick: 20 times / sec |
|
Automatic / manual range |
√ |
√ |
|
True RMS |
√ |
√ |
|
Bandwidth |
50kHz |
1kHz |
|
The duty ratio |
0.1%~99% |
0.1%~99% |
|
Diode test |
√ |
√ |
|
Continuity beeper |
√ |
√ |
|
Four wire resistance measurements |
√ |
√ |
|
dBm |
√ |
√ |
|
MAX/MIN/AVG |
√ |
√ |
|
Relative value measurement |
√ |
√ |
|
Data Hold |
√ |
√ |
|
The reference junction compensation |
√ |
√ |
|
°C/ ° F conversion |
√ |
√ |
|
Change rate |
√ |
√ |
|
Input impedance |
10MΩ |
10MΩ |
|
Data recording |
Work in 50000 groups were recorded |
Work in 50000 groups were recorded |
|
Communication interface |
Configurable isolation USB, isolated RS232 communication |
||
Online communication |
Support ASCⅡcan realize remote control instrument by the device driver software. The powerful function, friendly man-machine interface, the user can conveniently obtain multiple data parameters of instrument, and the data storage, processing, management, access to data is displayed in the graphical or tabular form. |
||
Auto power-off |
√ |
√ |
|
Display type |
VFD |
VFD |
|
Power Supply |
220V±10%AC or 110V±10%AC,50Hz or 60Hz |
220V±10%AC or 110V±10%AC,50Hz or 60Hz |
|
Power |
About 3W |
About 3W |
|
Safety |
CAT II 300V |
CAT II 300V |
|
Electromagnetic compatibility |
IEC61326-1,Group1,Class B |
IEC61326-1,Group1,Class B |
|
Size |
245 × 220 × 82(mmdgt) |
245 × 220 × 82(mmdgt) |
|
Weight |
About 2kg |
About 2kg |
|
Standard Quantity Per Carton |
4pcs |
4pcs |
|
Standard Carton Measurement |
650mm*390mm*370mm |
650mm*390mm*370mm |
|
Standard Carton Cross Weight |
21Kg |
21Kg |
Contact Person: Mrs. sales
Tel: +86 13924679853
Fax: 86-755-82268753-262