Product Details:
|
Color: | Black And Orange | Packing: | Color Box |
---|---|---|---|
Weight: | Approx 550g | Power: | DC 9V |
Dimension: | 196mm×92mm×54mm | Product Name: | Three Phase Digital Phase Meter |
Current Clamp Length: | 2m | Test Line Length: | 1.5m |
High Light: | DC9V Digital Phase Meter,DC9V Electric Power Detector,sine wave Digital Phase Meter |
Multi Functional DC9V Digital Phase Meter Electric Power Detector
VICTOR 4300 Three Phase Digital Phase Meter Multi-Functional Meter Electric Power Detecter Phases Current Voltage
Instruction
The 4300 Three Phase Digital Phase Meter is a well-developed multi-functional meter specifically designed for field testing, featuring high accuracy, high stability, low power consumption, easiness to use and so on. It can directly measure AC voltage and AC current without opening the measured circuit, phases between three voltages, three currents and phase between the voltage and current; in addition, the power factor and power of the circuit can be indirectly measured, it can also be used to distinguish three-phase sequence, transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc.
The 4300 Three Phase Digital Phase Meter has a 240dots×160dots LCD screen, all the test data display on the screen simultaneously, vector diagram indication, and looks exquisite and comfortable.
The 4300 Three Phase Digital Phase Meter applies to electric power, petroleum chemical industry, metallurgy, railway, and meteorology, industrial and mining enterprises, scientific research institutions, measurement sector and so on.
Technical Specification
Influence Quantity | Base Condition | Working Conditions | Remark |
Ambient Temp | 23℃±1℃ | -10℃~40℃ | |
Ambient Humidity | 40%~60% | <80% | |
Signal Waveform | sine wave | sine wave | β=0.05 |
Signal Frequency | 50HZ±1HZ | 45HZ~65HZ | |
Meter Working Volt | 9V±0.1V | 9V±1V | |
External Electric Magnetic Field | To be avoided | ||
Measured Wire Position | Measured wire at approximately the geometric center of the clamp |
Function | Three Phase, AC current, AC voltage, AC leakage current, direct test of phase sequence; transformer groups, inductive, capacitive circuit discrimination; indirect test of power factor and power |
Power | DC9V alkaline batteries(1.5V AA×6) |
Consumption | About 80mA at most with enabled backlight, battery working continuously for about 10 hours |
About 5mA with disabled backlight, battery working continuously for about 16 hours | |
Display Mode | LCD display, 240dots×160dots |
Meter Size | Length, Width, Height:196mm×92mm×54mm |
Clamp Size |
acuminate current clamp:7.5mm×13mm (4300) round current clamp:35mm×40mm (ETCR4400) |
Sampling Rate | About 2 times/second |
Measurement Range | AC Voltage:0.00 V~600V |
AC Current:0.0mA~20.0A | |
Phase:0~360° | |
Measured Signal Amplitude in Phase Test | Votage amplitude range:10V~600V |
Current amplitude range:20mA~10.00A | |
Data Hold | Press HOLD key to keep data, "DH" symbol appears |
Data Storage | 99 sets |
Automatic Shutdown | Automatic shutdown about 15 minutes later after launching to reduce battery consumption |
Backlighting | Suitable for dark place and nightly use |
Voltage Detection | Low battery symbol “ " appears to remind the replacement of battery when the battery voltage drops below 7.2V. |
Weight | Main Unit about 550g(with battery),acuminate current clamp about 170g×3, round current clamp about 185g×3, test line about 250g |
Test Line Length | 1.5m |
Current Clamp Length | 2m |
Working Temperature and Humidity | -10℃~40℃; below 80%Rh |
Storage Temperature and Humidity | -10℃~60℃; below 70%Rh |
Input Impedence | Testing voltage the input impendence is 2MΩ |
Withstand Voltage | Withstand 1000V/50Hz sine wave AC voltage for 1 minute between the meter lines and shell; Withstand 500V/50Hz AC voltage sine wave for 1 minute between the two voltage inputs |
Insulation | ≥10MΩ between meter lines and shell or between the two voltage inputs |
Structure | Double insulation, with insulation vibration-proof sheath |
Category | Measurement Range | Resolution | Intrinsic Error |
Voltage | AC 0.0V~600V | 0.01V | ±(1.5%rdg+3dgt) |
Current | AC 0.0mA~20.0A | 0.1mA | ±(1.5%rdg+3dgt) |
Phase | 0.0°~360° | 0.1° | ±3° |
Contact Person: Mrs. sales
Tel: +86 13924679853
Fax: 86-755-82268753-262